RTS PLUS builds hot water production into the architecture of the building. The receivers work horizontally and become pergolas, shading canopies or roofs, with no tilted panels on the roof.
At sunrise, each receiver turns its mirror towards the sun.
12:00
Sunlight is concentrated nineteen times onto the absorber tube and heats the water.
16:00
Tracking continues all afternoon: more hours of output than a fixed collector.
19:00
Above, an architectural element. Below, shade and hot water.
07:00
Scroll through the day ↓
One system, two perspectives
Universal in integration. Universal in control.
Fits any buildingNew build or refurbishment. Pergola, canopy, façade, roof, car park or greenhouse.
Connects to any systemDomestic hot water, pools and underfloor heating, backed up by a boiler or heat pump.
Controlled remotelyElectronic temperature control and operational monitoring.
For the architect
Designed with the building.
Horizontal lines and a slender profile, with no tilted panels
Modules that follow the grid and geometry of the project
Aluminium profiles with a continuous finish
Useful shade and a clear roof: the fifth façade stays clean
For the engineer
Proven performance.
19× solar concentration onto an absorber tube
Sun tracking throughout the day
Solar Keymark certification PSK-002/2026
Energy simulation for regulatory compliance
01 — Architecture
Part of the design, not an add-on.
The solar system is no longer equipment to hide on the roof. Designed by the architect, one element shades, shelters and produces energy: a pergola, a canopy over the façade, the roof of a pool or a car park.
The façade shades, filters the light and heats the pool.
Integration types
Terrace pergolaOffice façadeHouse with poolAgricultural greenhouse
Sectors
HotelsHospitalsGymsApartmentsCampsitesSchools
02 — Control and safety
Heats what is needed. Protects itself.
When the tank reaches the set temperature, the receivers stop tracking and turn vertical. If the power fails and the pump stops, the receiver's battery takes it to the safe position.
No consumption, no overheatingHolidays or a second home: once the set temperature is reached, the receivers stop heating.
Power cutWithout circulation, the receiver would overheat within seconds. On battery power, it turns vertical.
Resumes on its ownWhen there is consumption again, or when power returns, it goes back to solar tracking.
Tap the video to watch it full screen.
03 — Modularity
From the roof of a house to the façade of a hotel.
RTS PLUS is built in modules. Each module holds 2 to 10 receivers stacked vertically on a 6 m technical column. Sideways, modules join by sharing columns, with no technical limit; upwards, a new level is mounted on another column. Choose the home, the litres of hot water, or build it freely.
Bedrooms
Sunaitec rule: people = bedrooms plus one, with 60 L of hot water per person per day (the standard assumes 40 L). The tank rounds up to the next commercial size and each receiver serves 100 L.
For hotels, pools, care homes or industry, count 100 L per receiver. The final design is done with an energy simulation based on the consumption profile and the location.
Minimum 2 receivers. The technical column is a 6 m profile holding up to 10 receivers; above that, each level is a new column. Sideways there is no technical limit.
Front view · dimensions in metres
0receivers
0m² gross area
0kW at 1000 W/m²
0litres of storage
0width × height (m)
Datasheet dimensions: 3,100 mm receiver between 120 mm columns, 600 mm between receivers, 6 m technical column. Per receiver, 1.14 m² gross area and 591 W (G = 1000 W/m², Solar Keymark). Indicative values.
04 — How it works
Multifunction solar structure.
Technical columns support adjustable solar thermal receivers. Active sensors keep each receiver aligned with the sun, so it produces more than a fixed collector. It is the result of research in materials engineering, optics, thermodynamics, robotics and digital electronics.
Output per receiver, aperture area, dimensions, operating pressure, heat losses and mounting conditions: all in the datasheet, sent straight to your email.
The design manual and installation instructions are provided to installers and designers on request.
PDFRTS PLUS datasheet
Tracking concentrating solar collector · Solar Keymark PSK-002/2026
Rated output per receiver
Aperture area and dimensions
Stagnation temperature and losses
Operating pressure and receivers per module
For your home
Already have solar thermal? Give it a second life.
Pumped flat-plate collectors lose efficiency over the years. We replace them with RTS PLUS and reuse whatever is still in good condition.
We assess your systemWe check the collectors, the tank and the pipework, and tell you what can be reused.
We remove the old collectorsWe dismantle the old system and prepare the roof or terrace.
We install RTS PLUSWe connect the receivers to your system and leave everything running and monitored.
We work with architects and engineers on the design of the solution, send the technical dossier and carry out the energy simulation for regulatory compliance. Representatives, distributors and business customers, in Portugal or abroad, can ask for our partnership terms.